Loading...
HomeMy WebLinkAbout3/25/2021 - Regular TOWN OF VINTON 311 S. POLLARD STREET VINTON, VIRGINIA 24179 PHONE: (540) 983-0605 FAX: (540) 983-0621 ANITA MCMILLAN EMAIL: amcmillan@vintonva.gov PLANNING AND ZONING DIRECTOR March 19, 2021 TO: VINTON PLANNING COMMISSION Mr. Keith Liles, Chair Mr. David “Dave” Jones, Vice-Chair Mr. Robert “Bob” Benninger Mr. Andrew “Ty” Braxton Ms. Sarah Reid RE: Virtual Work Session via Zoom Thursday, March 25, 2021 at 6:30 p.m. A virtual work session of the Planning Commission will be held on Thursday, March 25th at 6:30 p.m., and a link to the Zoom meeting will be provided via email prior to the meeting. Please see the enclosed agenda and supporting materials for the meeting. Note that a joint virtual public hearing of the Town Council and Planning Commission for the proposed rezoning will be held via Zoom on Tuesday, April 6, 2021, at 7:00 p.m. The purpose of the work session is to receive comments and discuss the request to rezone the historic Gish Mill properties, located at 350 and 0 Gus Nicks Boulevard, Vinton, Virginia, Tax Map Numbers 060.11-04-22.00-0000 and 060.11-04-23.00-0000, from M-1 Limited Industrial to Mixed Use Development (MUD) District, and to review the proposed Capital Improvement Plan (CIP) of the Town of Vinton. Please let me know if you are UNABLE to attend the Zoom work session on March 25th or the joint public hearing on April 6th as soon as possible by emailing me at amcmillan@vintonva.gov or calling me at 540-983-0605. Thank you. Sincerely, Anita J. McMillan Planning and Zoning Director Enclosures c: Richard “Pete” Peters, Town Manager Anne Cantrell, Finance Director/Treasurer Nathan McClung, Principal Planner Vinton Planning Commission Thursday, March 25, 2021 Work Session - 6:30 p.m. PARTICIPATION WILL BE BY ELECTRONIC COMMUNICATIONS PURSUANT TO SECTION 15.2-1413, CODE OF VIRGINIA (1950), AS AMENDED, ORDINANCE NO. 1016 AND SECTION 4-0.01(G) OF CHAPTER 1289 OF THE 2020 ACTS OF THE VIRGINIA GENERAL ASSEMBLY The Vinton Planning Commission will hold a Work Session at 6:30 p.m. on Thursday, March 25, 2021, using electronic communication means without the public being present. Participation by Planning Commission members, staff, and the public will only be available through electronic means. The public will have access to observe the Work Session through a livestream on the Town’s Facebook page at www.facebook.com/vintonva. Citizens may register to speak at the work session by calling the Town Clerk’s Office at 540-983-0607 or by sending an email to sjohnson@vintonva.gov by 12 Noon on Wednesday, March 24, 2021. Once registered, the citizen who wishes to address the Planning Commission will be provided the Zoom meeting information and will be allowed to join the meeting and address the Planning Commission by electronic means. AGENDA Consideration of: WORK SESSION – 6:30 P.M. I. Call to Order—Roll Call II. CONFIRMATION THAT MEETING IS BEING HELD IN ACCORDANCE WITH ORDINANCE NO. 1016 AND SECTION 4-0.01(G) OF CHAPTER 1289 OF THE 2020 ACTS OF THE VIRGINIA GENERAL ASSEMBLY III. Briefings 1. To discuss and receive comments on the proposed rezoning of the historic Gish Mill properties, located at 350 and 0 Gus Nicks Boulevard, Vinton, Virginia, Tax Map Numbers 060.11-04-22.00-0000 and 060.11-04-23.00-0000, from M-1 Limited Industrial to Mixed Use Development (MUD) District. 2. To receive the adopted FY 2021 Capital Improvement Plan (CIP) and to review, discuss, and receive comments on the proposed Fiscal Year (FY) 2022 - 2028 CIP of the Town of Vinton. IV. Comments of Planning Commissioners and Planning Staff V. Adjournment of Work Session Vinton Municipal Building 311 S. Pollard Street Vinton, VA 24179 Phone (540) 983-0605 Fax (540) 983-0621 Mr. David “Dave” Jones, Vice-Chair Mr. Robert “Bob” Benninger Mr. Andrew "Ty" Braxton Ms. Sarah Reid STAFF REPORT PETITIONER: Town of Vinton, VA PREPARED BY: Nathaniel McClung CASE NUMBER: PC-21-001 DATE: March 8, 2021 Application Information Request: Rezoning Request (M-1 to MUD) Owner: Town of Vinton Applicant: Town of Vinton Site Address/Location: 350 and 0 Gus Nicks Boulevard, Vinton, Virginia Tax Parcel ID #: 060.11-04-22.00-0000 and 060.11-04-23.00-0000 Lot Area: 1.154 AC Zoning: M-1 Limited Industrial District Existing Land Use: Currently vacant; previous use was a farm supply retail store and warehouse. Proposed Land Use: Mixed-use property that will accommodate restaurant, retail, residential, and lodging uses. Specified Future Land Use: General Commercial A. NATURE OF REQUEST Petition of the Town of Vinton, to rezone the historic Gish Mill properties, from M-1 Limited Industrial to Mixed Use Development (MUD) District, in order for the properties to be redeveloped into a mixed- use property that will accommodate restaurant, retail, residential, and lodging uses. The properties are located at 350 and 0 Gus Nicks Boulevard, Vinton, Virginia, Tax Map Numbers 060.11-04-22.00-0000 and 060.11-04-23.00-0000. B. APPLICABLE REGULATIONS The property is currently zoned M-1 Limited Industrial District which does not allow mixed uses to be located within the same building. Mixed residential and business uses within the same building are currently only allowed in the business districts such as GB General Business (under certain conditions), CB Central Business (under certain conditions), PD Planned Development, or MUD Mixed Use Districts. Mixed use is intended as an improvement over traditional, segregated-use zoning. It is a way of creating a multi-use, multi-purpose building or set of buildings, incorporating some combination of residential, commercial, industrial, office, institutional, or other land uses as part of the overall environment. The Town’s Mixed Use Development (MUD) district was adopted on April 21, 2015. The intent of the Mixed Use Development district is to encourage the orderly development of mixed residential/commercial sites and to encourage innovative development patterns that create a desirable environment, particularly for several vacant parcels, buildings, and underutilized properties located throughout the Town, which contain a number of constraints to conventional development. C. ANALYSIS OF EXISTING CONDITIONS Background – Being the founding structure for the Town of Vinton, the Gish Mill site bears a substantial amount of historical significance for the locality. In fact, the Mill is featured as the crown jewel of the Town’s seal. Although the mill operated continuously since the 1770s, in its final years of occupancy it was used as a farm supply retail store and warehouse which ultimately closed in December 2014. Unfortunately, decades of deferred maintenance and exposure to the elements contributed to its current deleterious condition and the necessity of major repairs and improvements. Beyond its historical significance, the mill site is currently positioned both geographically and strategically to have a catalytic impact on the area’s economic, vocational, and cultural growth. In addition to being within the designated Downtown UDA, the project site is specifically located along the major gateway to the Downtown corridor and is the first major landmark individuals see when they enter the Town of Vinton on Gus Nicks Boulevard. Reactivating this commercial and historic mill at the gateway to Vinton will provide a vibrant welcome to residents, and visitors, and to those passing through on their way to Smith Mountain Lake and Blue Ridge Parkway. The Town of Vinton purchased the 1.154 acres property in October of 2015, due to the historical significance to the community and the Town’s eventual charter in 1884. Council’s desire has been to preserve and encourage the structure to be rehabilitated and eventually returned to commercial use. Following the issuance of a Request for Proposal (RFP) in 2019, the Town of Vinton received a formal proposal from Gish Mill Davii, LLC, to convert the historic property into a mixed- use development with the following uses: a small restaurant, a seasonal market, a speakeasy in the basement, and the conversion of the original mill structure, concrete silos, and upper floors of the original mill structure into lodging with potential use for apartment units (3-10 rooms). The anticipated tenant to operate the restaurant and lodge has already been secured for the project. Since the acquisition, the Town of Vinton has completed Phase I and Phase II environmental assessments, has completed the historic reviews necessary for the property to be preliminary determined for individual listing on the National Register by the Department of Historic Resources (DHR), and obtained grant funds from two state government agencies which make the project financially feasible. The first grant from the DHR Emergency Supplemental Historic Preservation Fund (ESHPF) grant program includes $250,000 in available funding for repair and stabilization work to take place on the property. The second grant to the Town is to be administered in the form of a loan of $468,750 through the Economic Development Authority (EDA) from the Department of Housing and Community Development (DHCD) Industrial Revitalization Fund (IRF). The redevelopment project will generate private investment in excess of $1.9 Million and establish the creation of approximately 41 jobs and result in the rehabilitation of a historic, yet currently-blighted property that is located on one of four main gateway entrances into the Town with an average daily traffic count of 21,000 vehicles per day based on 2019 Virginia Department of Transportation (VDOT) data. The site is also located along the proposed Glade Creek Greenway extension, which will link Downtown Vinton and Vinyard Park to the extensive Roanoke Valley Greenway system. The Town of Vinton has also secured Virginia Department of Transportation (VDOT) Surface Transportation Block Grant (STBG) funds to construct a pedestrian mid-block crossing on Gus Nicks Boulevard to provide a safe means of travel to the Gish Mill site from the soon to be constructed Glade Creek Phase II project and the newly redeveloped 84-unit apartment building (Billy Byrd Apartments). Overall, this project is currently of the highest priority for the Town of Vinton in the realm of redevelopment and there is not another vacant and deteriorated property that has the potential for the level of economic and social impact that this site could bring to the area. Location – 350 and 0 Gus Nicks Boulevard, Vinton, Virginia. Former Holdren’s County Store. The parcels can be accessed from Gus Nicks Boulevard and West Madison Avenue. Topography/Vegetation – The existing structure is located adjacent to Glade Creek on a level lot that is comprised mostly of impervious surfaces. In relation to its special location, the Gish Mill, in serving its historic milling purposes, is located in the regulatory floodway and Special Flood Hazard Areas (SFHA) of the Glade Creek floodplain. Because the Town of Vinton is a FEMA Community Rating System (CRS) Class 8 Community, Town staff are diligent in administering the highest forms of regulatory controls for development and activities in the Town’s floodplain areas. Adjacent Zoning and Land Uses – The land uses within the vicinity of the subject property are summarized below. Direction from Property Zoning District Land Use (Chalaine’s) and Sign Manufacturing (Sav’ On Signs) D. ANALYSIS OF PROPOSED DEVELOPMENT Site Layout/Architecture - The developer’s intended use for the mill site is to incorporate several value- added compatible uses, which launch from popular trends that work very well with the open format historic space. The building will be designed to feature several uses that take advantage of the creekside location, the unconventional construction methods, and varying dimensions and angles featured by the mill space. The specific uses include a small restaurant, a seasonal market, a speakeasy in the basement, and the conversion of the original mill structure, concrete silos, and upper floors of the original mill structure into lodging or apartments (3-10 units). The anticipated tenant to operate the restaurant and lodge has already been secured for the project. The development also includes substantial outdoor spaces including dining, deck, and patio space. The historic “sluice” will be utilized as an intimate seating area with stairs that cascade down to the creek. Based on the preliminary floor plans, the development will include: (1) Restaurant (back of house, kitchen, and dining space): 5,030 square feet (First floor) (2) Market: 1,250 square feet (First floor) (3) Speakeasy: 1,296 square feet (Basement) (4) Original Mill and silos converted into lodging/apartments: 5,800 square feet (Second and Third floor) (5) Outdoor dining, deck and patio space: 3,564 square feet (incl. deck and addition to existing slab) Many of the existing mature trees will be retained. The existing sidewalk connections will be retained and will be extended into the site providing pedestrian access from each direction of Gus Nicks. The existing asphalt parking areas will be redeveloped and landscaped for 28 off-street parking spaces including two accessible spaces. Additionally, there exists an opportunity for a substantial overflow parking area adjacent to West Madison Avenue. The historic building will be preserved and sensitively adapted for mixed uses. The building will retain its architectural character and its environmental setting. Visible changes to the exterior of the property and building will be minor. The Mixed-Use Development District will allow this space to be used for flexible space, offering opportunities for community activities, music, and special events perhaps including “movie nights” utilizing the historic building façade for an outdoor projection area. Please see attached survey, property map, aerial photography, and conceptual site plan including parking areas and floor plans of the structure in Appendix A. The Development Team will present a conceptual 3- D rendering of the future interior and exterior renovations to the property to Town Council during the briefing on this request. If the rezoning request for the parcels is approved by the Town Council, a formal site plan for the Project must be submitted for review and approval by the Town of Vinton and County of Roanoke. Parking – As shown in the submitted conceptual plan, the internal Gish Mill site will allow 28 off-street parking spaces including two accessible spaces. There is also opportunity for parking adjacent to West Madison Avenue that could potentially provide over 13 off-site spaces, which will bring the total parking space count to about 41. Site Access – The parcel can currently be accessed from Gus Nicks Boulevard and West Madison Avenue via two (2) commercial entrances that accommodate for both ingress and egress. The Town of Vinton has also secured VDOT Surface Transportation Block Grant (STBG) funds to construct a pedestrian mid- block crossing on Gus Nicks Boulevard to provide a safe means of travel to the Gish Mill site from the soon to be constructed Glade Creek Phase II project and the newly redeveloped 84-unit apartment building (Billy Byrd Apartments). Utilities – Public water and sewer services are available for the existing structure. E. NO-RISE CERTIFICATION (HYDROLOGIC AND HYDRAULIC STUDY) The Town utilized the consulting services of Draper Aden Associates to verify that the proposed redevelopment project would not cause a rise in the base flood elevation. The consultants were able to utilize the plans of the proposed improvements from the development team and implement them into the flood models. The conclusion of this H&H study was that the proposed project will not cause a rise in the base flood elevations. Both the “Memorandum” from the consultant and the signed “No-Rise Certificate” can be found in Appendix B of this report. The Gish Mill structure meets the definition of a “historic structure” set out in the definition section of Division 13, FO Floodplain Overlay District, of the Vinton Zoning Ordinance. Specifically, the Gish Mill structure meets the definition of subsection (a) pertaining to being “preliminary determined” for individual listing on the National Register. The letter attached in Appendix C states that the Virginia “Department of Historic Resources has evaluated the property and has determined that is appears to be eligible for inclusion in the Virginia Landmarks Register. In accord with the provisions of Sec. 58.1-339.2 of the Code of Virginia, then, the property is a certified historic structure.” Both the Town of Vinton and the Development Team understand that meeting this definition does not automatically exempt this project and its associated activities from the requirements of the floodplain ordinance. However, specific variances from the floodplain ordinance are being requested by the Town of Vinton with a public hearing of the Board of Zoning Appeals scheduled for March 30, 2021. Additionally, the Town and the Development Team understand that Historic structures undergoing repair or rehabilitation that would constitute a substantial improvement as defined above, must comply with all requirements of this division that do not preclude the structure's continued designation as a historic structure. Documentation that a specific ordinance requirement will cause removal of the structure from the National Register of Historic Places or the state inventory of historic places must be obtained from the Secretary of the Interior or the state historic preservation officer. Any exemption from ordinance requirements will be the minimum necessary to preserve the historic character and design of the structure. To aid in this process, all of the work being completed during both the repair and stabilization phase and the overall redevelopment phase will be reviewed and approved of by the Department of Historic Resources before it proceeds. In fact, this is a requirement of both the DHR grant guidelines and the overarching commitment in seeking historic tax credits at the end of this redevelopment project. F. COMPREHENSIVE PLAN/FUTURE LAND USE The 2004 – 2024 Town Comprehensive Plan designates this property and the surrounding properties to the southeast as a general commercial land use area. The properties to the west of this property (across Gus Nicks Boulevard) are designated as parks and recreation, community facilities, and high density residential uses. The properties to the west were rezoned to Mixed Use Development (MUD) in 2016 to allow for the existing vacant school buildings to be adaptively reused as residential and recreational/small business flex space. G. STAFF CONCLUSION Approval of the proposed rezoning from M-1 Limited Industrial to Mixed Use Development (MUD) District would allow the existing Gish Mill property to be redeveloped into a mixed-use property that will accommodate restaurant, retail, residential, and lodging uses. The proposed redevelopment of the historic Gish Mill property would be consistent with the existing uses of the adjoining properties to the west and southeast which contain both residential and commercial uses. The redevelopment of the property will promote and encourage the economic vitality of the community and preserve a historic building while providing increased economic investment. Additionally, the proposed uses will not adversely affect adjoining properties and will enhance the neighborhood by taking an important historical structure and repurposing it for a suitable alternative use that maintains the historic architecture and setting of the buildings. Adequate utilities and public facilities are already in place to serve the proposed end uses. Overall, the rezoning of the parcels included in the Gish Mill site will be the third MUD rezoning process in the Town of Vinton. The other two projects that involved the rezoning of parcels to MUD in the Town of Vinton included the Roland E. Cook Lofts and the Billy Byrd Apartment projects, which were formerly owned by Roanoke County Board of Supervisors. The Roland E. Cook Lofts and Billy Byrd Apartments projects have proven to be a benchmark of success in the revitalization of historic buildings through the utilization of historic tax credit programs and local governmental (County of Roanoke and Town of Vinton) coordination. Attachment A Redevelopment Project Survey, Property Map, Aerial Photography, and Conceptual Site Plan with 3-D Renderings of Potential Interior and Exterior Renovations 914.5 ABOVE 902.0 BELOW 915.25 F.F.E. 915.0 913.5 908.10 914.75 RAMP 913 5% 911.5 DECK 3' CONC WALK BELOW + + + ++ + + A L101 L201 ex. SLUICE DECK B L101 L201 CONC. HEARTH FIRE exist. exist. exist. exist. exist. D L101 L201 901 BELOW + (3)2 x12 SYP NO. 2 @1'-4" OC 2 x12 JOISTS SYP NO. 2 @1'-4" OC (3)2 x12 8x8 WOOD POST TYP W/ MPB 88 Z MOMENT POST BASE W/ 2'-6" DIA CONCRETE CAISSON REINF. W/8 #4S VERTICAL, #3 TIES @ 6"OC 2 x12 JOISTS SYP NO. 2 @1'-4" OC (3)2 x12 BAND TYP 5% 904.5 + 5% 902 BELOW+ +915 ex. sw NEW 3' CONC SW MATCH EXIST. 908.5 + 906.5 + 5% 5% SUPPLEMENTAL CONTOUR DATA FROM COUNTY GIS SUPPLEMENTAL CONTOUR DATA FROM COUNTY GIS DN UP UNIT 1 UNIT 2 TOILETSVEST BACK OF HOUSE DINING KITCHEN TOILETS MARKET UNIT 3 DINING PLANTING SCREENED PORCH 915.25 F.F.E. HISTORIC PROPERTY LINE: 1988 SURVEY ex. TREES TYP 28 ON-SITE PARKING CANOPY ABOVE exist. sw ex. pipe ex. OHU ex. inlet REPAVE EX. PARKING AREA REMOVE EX PVMT ex. guardrail FUTURE CROSSWALK CONNECTION TO GREENWAY & THE BILLY BYRD Date: Revisions: Review By: Project No. Drawn By: Sheet No. STUDIO HILL Landscape Architecture Architecture Community Planning Historic Preservation 120 W. Campbell Ave. SW Roanoke, VA 24011 tel: 540-342-5263 fax: 540-345-5625 www.hillstudio.com Seal 10 9 8 7 6 5 4 3 2 1 G F E C B GISH MILL REVITALIZATION TOWN OF VINTON ROANOKE COUNTY, VA GISH MILL DAVII A 5 4 3 2 1109876 CLL DPH 1957.01 3/12/2021 Title: 0 SCALE IN FEET 1"= '-0" 10 5 10 20 30 10 LAYOUT AND L-101 MATERIALS PLAN SEE SHEET L102 FOR CONTINUATION FFE 916.41 ex.914.21 5% 5% + C L102 L201 DECK REMOVE PORTION OF STRUCTURE exist. conc slab exist. DECK ABOVE NEW CONC. REVETMENT WALL 8x8 WOOD POST TYP W/ MPB 88 Z MOMENT POST BASE W/ 2'-6" DIA CONCRETE CAISSON REINF. W/8 #4S VERTICAL, #3 TIES @ 6"OC 2 x12 JOISTS SYP NO. 2 @1'-4" OC (3)2 x12 BAND TYP STREAMBANK STABILIZATION SUPPLEMENTAL CONTOUR DATA FROM COUNTY GIS DN DN TOILETS MARKET FUTURE TRAIL CONNECTION STREAMBANK STABILIZATION 915.25 F.F.E. HISTORIC PROPERTY LINE 1988 SURVEY ex. TREES TYP OFF-SITE PARKING 13 28 ON-SITE PARKING SHOPS HISTORIC PROPERTY LINE 1988 SURVEY FU T U R E T R A I L C O N N E C T I O N REPAVE EX. PARKING AREA Date: Revisions: Review By: Project No. Drawn By: Sheet No. STUDIO HILL Landscape Architecture Architecture Community Planning Historic Preservation 120 W. Campbell Ave. SW Roanoke, VA 24011 tel: 540-342-5263 fax: 540-345-5625 www.hillstudio.com Seal 10 9 8 7 6 5 4 3 2 1 G F E C B GISH MILL REVITALIZATION TOWN OF VINTON ROANOKE COUNTY, VA GISH MILL DAVII A 5 4 3 2 1109876 CLL DPH 1957.01 3/12/2021 Title: 0 SCALE IN FEET 1"= '-0" 10 5 10 20 30 10 LAYOUT AND L-102 MATERIALS PLAN SEE SHEET L101 FOR CONTINUATION DN DN DN UP UNIT 1 UNIT 2 TOILETSVEST BACK OF HOUSE DINING KITCHEN TOILETS MARKET UNIT 3 DINING GREENWAY CORRIDOR HISTORIC PROPERTY LINE 1988 SURVEY FUTURE TRAIL CONNECTION THE BILLY BYRD SHOPS THE GISH MILL Date: Revisions: Review By: Project No. Drawn By: Sheet No. STUDIO HILL Landscape Architecture Architecture Community Planning Historic Preservation 120 W. Campbell Ave. SW Roanoke, VA 24011 tel: 540-342-5263 fax: 540-345-5625 www.hillstudio.com Seal 10 9 8 7 6 5 4 3 2 1 G F E C B GISH MILL REVITALIZATION TOWN OF VINTON ROANOKE COUNTY, VA GISH MILL DAVII A 5 4 3 2 1109876 CLL DPH 1957.01 3/12/2021 Title: LAYOUT AND L-103 CONTEXT PLAN 0 SCALE IN FEET 1"= '-0" 30 15 30 60 90 30 DN DN DN UP UNIT 1 UNIT 2 TOILETSVEST BACK OF HOUSE DINING KITCHEN TOILETS MARKET UNIT 3 DINING HISTORIC PROPERTY LINE 1988 SURVEY SHOPS THE GISH MILL Date: Revisions: Review By: Project No. Drawn By: Sheet No. STUDIO HILL Landscape Architecture Architecture Community Planning Historic Preservation 120 W. Campbell Ave. SW Roanoke, VA 24011 tel: 540-342-5263 fax: 540-345-5625 www.hillstudio.com Seal 10 9 8 7 6 5 4 3 2 1 G F E C B GISH MILL REVITALIZATION TOWN OF VINTON ROANOKE COUNTY, VA GISH MILL DAVII A 5 4 3 2 1109876 CLL DPH 1957.01 3/12/2021 Title: ENVIRONMENTAL L-104 CONTEXT MAP 0 SCALE IN FEET 1"= '-0" 20 10 20 40 60 20 425' 995' 530' 730' DN DN DN UP UNIT 1 UNIT 2 TOILETSVEST BACK OF HOUSE DINING KITCHEN TOILETS MARKET UNIT 3 DINING PROJECT AREA 2.5% 5% Date: Revisions: Review By: Project No. Drawn By: Sheet No. STUDIO HILL Landscape Architecture Architecture Community Planning Historic Preservation 120 W. Campbell Ave. SW Roanoke, VA 24011 tel: 540-342-5263 fax: 540-345-5625 www.hillstudio.com Seal 10 9 8 7 6 5 4 3 2 1 G F E C B GISH MILL REVITALIZATION TOWN OF VINTON ROANOKE COUNTY, VA GISH MILL DAVII A 5 4 3 2 1109876 CLL DPH 1957.01 3/12/2021 Title: W.V.W.A. L-105 & SIGHT DISTANCES 0 SCALE IN FEET 1"= '-0" 50 25 50 100 150 50 Attachment B No-Rise Certification: No-Rise Certificate (Signed) and Memorandum of H&H Study ENGINEERING "NO-RISE" CERTIFICATION This is to certify that I am a duly qualified engineer licensed to practice in the State of . It is to further certify that the attached technical data supports the fact that proposed _will (Name of Development) not impact the 100-year flood elevations, floodway elevations and floodway widths on at published sections (Name of Stream) in the Flood Insurance Study for , (Name of Community) dated _ and will not impact the 100-year flood elevations, floodway elevations, and floodway widths at unpublished cross-sections in the vicinity of the proposed development. Attached are the following documents that support my findings: _____________________________________________________________ (Date) (Signature) (Title) (Address) (Seal) 2206 South Main Street • Blacksburg, VA • 24060 • 540.552.0444 • www.daa.com Charlottesville • Manassas • Newport News • Richmond • Virginia Beach Fayetteville • Raleigh P:\2021\00100\2100128\03-SDI\REPORTS\MEM - 21 0305 - 2100128 - Gish Mill No-Rise - AJH-CAH.docx Memorandum To:Mr. Nathan McClung Principal Planner Town of Vinton From: Carolyn Howard, PE, Draper Aden Associates Date: March 5, 2021 Project Name:Gish Mill Revitalization Project Number: 2100128-03 Subject:Glade Creek No-Rise Certification cc: Hill Studio: David Hill Draper Aden Associates: Andrew Hemmen Background Gish Mill Davii is proposing to renovate the exiting Gish Mill into a commercial and residential development. Gish Mill is an historic structure adjacent to Glade Creek and is within the creek’s regulatory floodplain and floodway. The proposed improvements were analyzed to confirm the impacts will not cause a rise in the base flood elevation. The proposed work is within a Special Flood Hazard Zone, identified as Zone AE on the attached FEMA Flood Insurance Rate Map No. 51161C0167G dated September 28, 2007. Flood Modeling As the first step, a duplicate effective model (DEM) was run using HEC-RAS 5.0 to check for changes in the base flood elevation (BFE) between the model and the original HEC-2 output, as provided by the Town. The following table shows the difference between the HEC-2 and DEM base flood elevations. Station HEC-2 BFE, feet DEM BFE, feet 4048 919.0 919.5 4150 918.7 919.2 4500 919.8 920.1 4950 924.0 924.1 5034 924.7 924.8 5046 924.7 925.0 The DEM was revised to include a new, existing conditions cross-sections at river station 4250; this is the corrected effective model (CEM). Elevations for the new cross-section was determined using the topography provided for this project; the elevations were adjusted by 0.65 feet to match the datum of MEMORANDUM to the Town of Vinton March 5, 2021 Page 2 of 2 the existing flood model. The following table shows the difference between the DEM and CEM base flood elevations. Station DEM BFE, feet CEM BFE, feet 4048 919.5 919.5 4150 919.2 919.3 4250 - 919.6 4500 920.1 919.5 4950 924.1 924.1 5034 924.8 924.8 5046 925.0 925.0 Cross-sections 4150 and 4250 were adjusted for proposed improvements as shown in the plans Gish Mill Revitalization, Sheet L-101 and L-201, dated January 25, 2021; this is the proposed model (PCM). The following table shows the difference between the CEM and PM base flood elevations. Station CEM BFE, feet Proposed BFE, feet 4048 919.5 919.5 0.0 4150 919.3 919.3 0.0 4250 919.6 919.6 0.0 4500 919.5 919.5 0.0 4950 924.1 924.1 0.0 5034 924.8 924.8 0.0 5046 925.0 925.0 0.0 Therefore the proposed project, based in the information received, does not cause a rise in the base flood elevation. ATTACHMENTS 1. FEMA FIRM 51161C0167G 2. Floodplain Overlay Map 3. Gish Mill Revitalization, Sheet L-101, dated January 25, 2021 4. Glade Creek HEC-RAS Summary Table (CEM and Proposed) 5. Glade Creek HEC-RAS Cross-Sections (CEM and Proposed) DESIGNED: AJH DRAWN: AJH CHECKED: CAH DATE: 3/5/2021 FIGURE FLOODPLAIN OVERLAY MAP NEW CROSS SECTION K1 STREAM STATION 4250 GISH MILL DEVELOPMENT SECTION:L STA:4500 SECTION:K STA:4150 SECTION:J STA:3500 Virginia Geographic Information Network (VGIN) ¯ X SCALE: 1" = 200' PROJECT: 2100128 GISH MILL REVITALIZATION GLADE CREEK NO RISE CERTIFICATION Draper Aden Associates Engineering Surveying Environmental Services 2206 South Main Street Blacksburg, VA 24060 540-552-0444 Fax: 540-552-0291 Richmond, VA Charlottesville, VA Hampton Roads, VA Raleigh, NC Fayetteville, NC Northern Virginia Virginia Beach, VA Legend PROPOSED CROSS- SECTIONS EXISTING CROSS- SECTIONS 1% Annual Chance Flood Hazard Regulatory Floodway Special Floodway Area of Undetermined Flood Hazard 0.2% Annual Chance Flood Hazard Future Conditions 1% Annual Chance Flood Hazard Area with Reduced Risk Due to Levee 0 200 400100 Feet HEC-RAS River: RIVER-1 Reach: Reach-1 Profile: PF 1 Reach River Sta Profile Plan Q Total Min Ch El W.S. Elev Crit W.S. E.G. Elev E.G. Slope Vel Chnl Flow Area Top Width Froude # Chl (cfs) (ft) (ft) (ft) (ft) (ft/ft) (ft/s) (sq ft) (ft) Reach-1 1 PF 1 CEM-CAH 12700.00 887.00 909.90 902.36 910.76 0.003281 9.12 2361.24 217.25 0.35 Reach-1 1 PF 1 PCM-CAH 12700.00 887.00 909.90 902.36 910.76 0.003281 9.12 2361.24 217.25 0.35 Reach-1 5 PF 1 CEM-CAH 12700.00 887.00 909.92 910.77 0.003267 9.11 2365.42 217.39 0.35 Reach-1 5 PF 1 PCM-CAH 12700.00 887.00 909.92 910.77 0.003267 9.11 2365.42 217.39 0.35 Reach-1 15 PF 1 CEM-CAH 12700.00 887.00 909.96 910.81 0.003238 9.08 2374.08 217.69 0.35 Reach-1 15 PF 1 PCM-CAH 12700.00 887.00 909.96 910.81 0.003238 9.08 2374.08 217.69 0.35 Reach-1 45 PF 1 CEM-CAH 12700.00 887.10 910.06 910.91 0.003237 9.08 2374.18 217.70 0.35 Reach-1 45 PF 1 PCM-CAH 12700.00 887.10 910.06 910.91 0.003237 9.08 2374.18 217.70 0.35 Reach-1 100 PF 1 CEM-CAH 12700.00 887.20 910.26 911.09 0.003166 9.01 2395.81 218.44 0.35 Reach-1 100 PF 1 PCM-CAH 12700.00 887.20 910.26 911.09 0.003166 9.01 2395.81 218.44 0.35 Reach-1 460 PF 1 CEM-CAH 12700.00 888.30 911.33 912.48 0.003909 10.11 2145.30 225.97 0.39 Reach-1 460 PF 1 PCM-CAH 12700.00 888.30 911.33 912.48 0.003909 10.11 2145.30 225.97 0.39 Reach-1 837 PF 1 CEM-CAH 12570.00 889.10 913.14 913.49 0.001451 6.43 3960.44 385.72 0.24 Reach-1 837 PF 1 PCM-CAH 12570.00 889.10 913.14 913.49 0.001451 6.43 3960.44 385.72 0.24 Reach-1 887 PF 1 CEM-CAH 12570.00 890.00 913.36 902.63 913.57 0.000963 4.98 4444.19 354.41 0.18 Reach-1 887 PF 1 PCM-CAH 12570.00 890.00 913.36 902.63 913.57 0.000963 4.98 4444.19 354.41 0.18 Reach-1 900 Bridge Reach-1 913 PF 1 CEM-CAH 12570.00 890.00 913.45 902.63 913.65 0.000946 4.95 4475.12 355.85 0.18 Reach-1 913 PF 1 PCM-CAH 12570.00 890.00 913.45 902.63 913.65 0.000946 4.95 4475.12 355.85 0.18 Reach-1 977 PF 1 CEM-CAH 12570.00 889.50 913.43 901.63 913.78 0.001170 5.27 3516.95 325.44 0.21 Reach-1 977 PF 1 PCM-CAH 12570.00 889.50 913.43 901.63 913.78 0.001170 5.27 3516.95 325.44 0.21 Reach-1 989.5 Bridge Reach-1 1002 PF 1 CEM-CAH 12570.00 889.50 913.61 901.63 913.94 0.001125 5.19 3573.92 326.23 0.20 Reach-1 1002 PF 1 PCM-CAH 12570.00 889.50 913.61 901.63 913.94 0.001125 5.19 3573.92 326.23 0.20 Reach-1 1052 PF 1 CEM-CAH 12570.00 889.60 913.14 914.40 0.003618 10.20 2024.21 217.91 0.39 Reach-1 1052 PF 1 PCM-CAH 12570.00 889.60 913.14 914.40 0.003618 10.20 2024.21 217.91 0.39 Reach-1 1100 PF 1 CEM-CAH 12570.00 889.70 914.10 914.66 0.001700 7.27 2943.00 240.33 0.27 Reach-1 1100 PF 1 PCM-CAH 12570.00 889.70 914.10 914.66 0.001700 7.27 2943.00 240.33 0.27 Reach-1 1435 PF 1 CEM-CAH 12570.00 890.30 914.62 915.29 0.001851 7.68 2645.11 208.96 0.28 Reach-1 1435 PF 1 PCM-CAH 12570.00 890.30 914.62 915.29 0.001851 7.68 2645.11 208.96 0.28 Reach-1 1620 PF 1 CEM-CAH 12570.00 890.80 914.94 915.69 0.002089 8.04 2564.30 239.04 0.30 Reach-1 1620 PF 1 PCM-CAH 12570.00 890.80 914.94 915.69 0.002089 8.04 2564.30 239.04 0.30 Reach-1 1700 PF 1 CEM-CAH 12570.00 891.00 915.01 915.94 0.002440 8.68 2241.07 220.89 0.32 Reach-1 1700 PF 1 PCM-CAH 12570.00 891.00 915.01 915.94 0.002440 8.68 2241.07 220.89 0.32 Reach-1 2160 PF 1 CEM-CAH 12400.00 892.00 916.23 917.07 0.002355 8.34 2351.02 234.44 0.31 Reach-1 2160 PF 1 PCM-CAH 12400.00 892.00 916.23 917.07 0.002355 8.34 2351.02 234.44 0.31 Reach-1 3500 PF 1 CEM-CAH 12400.00 894.80 918.75 918.91 0.000791 4.60 5299.46 468.85 0.17 Reach-1 3500 PF 1 PCM-CAH 12400.00 894.80 918.75 918.91 0.000791 4.60 5299.46 468.85 0.17 Reach-1 3790 PF 1 CEM-CAH 12200.00 895.00 918.90 919.28 0.001536 6.38 3865.89 463.08 0.24 Reach-1 3790 PF 1 PCM-CAH 12200.00 895.00 918.90 919.28 0.001536 6.38 3865.89 463.08 0.24 Reach-1 3951 PF 1 CEM-CAH 12160.00 896.00 919.29 908.39 919.46 0.000688 4.19 5503.24 616.81 0.17 Reach-1 3951 PF 1 PCM-CAH 12160.00 896.00 919.29 908.39 919.46 0.000688 4.19 5503.24 616.81 0.17 Reach-1 3999.5 Bridge Reach-1 4048 PF 1 CEM-CAH 12160.00 896.00 919.45 908.40 919.61 0.000659 4.12 5600.96 620.50 0.16 Reach-1 4048 PF 1 PCM-CAH 12160.00 896.00 919.45 908.40 919.61 0.000659 4.12 5600.96 620.50 0.16 Reach-1 4150 PF 1 CEM-CAH 12160.00 898.26 919.33 919.88 0.001948 6.86 2957.51 332.26 0.28 Reach-1 4150 PF 1 PCM-CAH 12160.00 898.26 919.33 919.87 0.001908 6.84 3003.40 332.34 0.28 Reach-1 4210 PF 1 CEM-CAH 12160.00 897.77 919.48 919.99 0.001675 6.25 2948.67 374.78 0.25 Reach-1 4210 PF 1 PCM-CAH 12160.00 897.77 919.46 919.98 0.001692 6.27 2927.01 385.56 0.25 Reach-1 4250 PF 1 CEM-CAH 12160.00 897.77 919.55 920.06 0.001644 6.20 2977.11 375.50 0.25 Reach-1 4250 PF 1 PCM-CAH 12160.00 897.77 919.61 908.77 920.12 0.001628 6.19 2986.83 387.05 0.25 Reach-1 4500 PF 1 CEM-CAH 12160.00 901.00 919.46 921.53 0.010281 12.60 1411.30 203.96 0.58 Reach-1 4500 PF 1 PCM-CAH 12160.00 901.00 919.53 921.57 0.010069 12.51 1425.64 205.50 0.58 HEC-RAS River: RIVER-1 Reach: Reach-1 Profile: PF 1 (Continued) Reach River Sta Profile Plan Q Total Min Ch El W.S. Elev Crit W.S. E.G. Elev E.G. Slope Vel Chnl Flow Area Top Width Froude # Chl (cfs) (ft) (ft) (ft) (ft) (ft/ft) (ft/s) (sq ft) (ft) Reach-1 4950 PF 1 CEM-CAH 12160.00 905.00 924.10 925.01 0.005194 9.54 2257.69 287.23 0.41 Reach-1 4950 PF 1 PCM-CAH 12160.00 905.00 924.10 925.01 0.005191 9.54 2258.06 287.24 0.41 Reach-1 5034 PF 1 CEM-CAH 12160.00 905.00 924.78 919.87 925.42 0.003570 8.18 2600.80 291.05 0.35 Reach-1 5034 PF 1 PCM-CAH 12160.00 905.00 924.78 919.87 925.43 0.003569 8.18 2601.08 291.06 0.35 Reach-1 5040 Bridge Reach-1 5046 PF 1 CEM-CAH 12160.00 905.00 924.95 919.88 925.57 0.003406 8.04 2648.74 292.53 0.34 Reach-1 5046 PF 1 PCM-CAH 12160.00 905.00 924.95 919.88 925.57 0.003408 8.04 2648.31 292.52 0.34 Reach-1 5095 PF 1 CEM-CAH 12160.00 904.00 924.77 926.05 0.006324 10.74 1910.11 248.30 0.47 Reach-1 5095 PF 1 PCM-CAH 12160.00 904.00 924.77 926.05 0.006327 10.74 1909.73 248.29 0.47 Reach-1 5348 PF 1 CEM-CAH 12160.00 904.00 926.39 912.06 926.50 0.000339 2.87 5606.84 454.14 0.11 Reach-1 5348 PF 1 PCM-CAH 12160.00 904.00 926.39 912.06 926.50 0.000339 2.87 5606.45 454.13 0.11 Reach-1 5360 Bridge Reach-1 5372 PF 1 CEM-CAH 12160.00 904.00 926.50 912.07 926.61 0.000364 2.88 5546.30 455.00 0.12 Reach-1 5372 PF 1 PCM-CAH 12160.00 904.00 926.50 912.07 926.61 0.000364 2.88 5545.92 454.99 0.12 Reach-1 5385 PF 1 CEM-CAH 12160.00 904.00 926.35 926.72 0.002382 6.70 3245.40 327.52 0.29 Reach-1 5385 PF 1 PCM-CAH 12160.00 904.00 926.35 926.72 0.002383 6.70 3245.10 327.52 0.29 Reach-1 5610 PF 1 CEM-CAH 12160.00 906.00 926.93 927.66 0.004184 8.66 2441.65 309.29 0.37 Reach-1 5610 PF 1 PCM-CAH 12160.00 906.00 926.93 927.66 0.004185 8.66 2441.41 309.29 0.37 Reach-1 6470 PF 1 CEM-CAH 12160.00 909.00 928.40 928.43 0.000296 2.25 9946.10 1061.11 0.10 Reach-1 6470 PF 1 PCM-CAH 12160.00 909.00 928.40 928.43 0.000296 2.25 9945.58 1061.10 0.10 Reach-1 7850 PF 1 CEM-CAH 12160.00 911.60 929.11 929.21 0.001326 4.13 5559.22 783.48 0.20 Reach-1 7850 PF 1 PCM-CAH 12160.00 911.60 929.11 929.21 0.001326 4.13 5558.93 783.47 0.20 Reach-1 8350 PF 1 CEM-CAH 12160.00 912.00 929.91 930.73 0.006017 8.83 2914.62 819.19 0.44 Reach-1 8350 PF 1 PCM-CAH 12160.00 912.00 929.91 930.73 0.006017 8.83 2914.47 819.19 0.44 Reach-1 8398 PF 1 CEM-CAH 12160.00 913.00 930.60 927.27 931.00 0.002721 6.58 4131.65 880.02 0.29 Reach-1 8398 PF 1 PCM-CAH 12160.00 913.00 930.60 927.27 931.00 0.002721 6.58 4131.54 880.02 0.29 Reach-1 8410 Bridge Reach-1 8422 PF 1 CEM-CAH 12160.00 913.00 930.82 927.04 931.26 0.003074 6.79 3937.31 884.44 0.30 Reach-1 8422 PF 1 PCM-CAH 12160.00 913.00 930.82 927.04 931.26 0.003074 6.79 3937.20 884.43 0.30 Reach-1 8460 PF 1 CEM-CAH 12160.00 912.00 931.11 931.38 0.001796 5.62 4568.91 725.01 0.26 Reach-1 8460 PF 1 PCM-CAH 12160.00 912.00 931.11 931.38 0.001796 5.62 4568.87 725.01 0.26 Reach-1 8800 PF 1 CEM-CAH 12160.00 912.00 931.63 931.72 0.000708 3.94 7259.69 957.45 0.17 Reach-1 8800 PF 1 PCM-CAH 12160.00 912.00 931.63 931.72 0.000708 3.94 7259.69 957.45 0.17 Reach-1 10265 PF 1 CEM-CAH 12160.00 918.00 933.41 933.91 0.004136 7.73 3063.31 466.15 0.38 Reach-1 10265 PF 1 PCM-CAH 12160.00 918.00 933.41 933.91 0.004136 7.73 3063.31 466.15 0.38 Reach-1 11560 PF 1 CEM-CAH 12160.00 922.00 936.37 936.54 0.001480 4.71 4988.35 659.58 0.23 Reach-1 11560 PF 1 PCM-CAH 12160.00 922.00 936.37 936.54 0.001480 4.71 4988.35 659.58 0.23 Reach-1 12030 PF 1 CEM-CAH 11679.00 922.00 936.92 937.05 0.001213 4.31 5661.44 833.15 0.21 Reach-1 12030 PF 1 PCM-CAH 11679.00 922.00 936.92 937.05 0.001213 4.31 5661.44 833.15 0.21 Reach-1 12070 PF 1 CEM-CAH 11679.00 922.00 936.30 933.16 937.64 0.009230 9.29 1257.69 825.74 0.55 Reach-1 12070 PF 1 PCM-CAH 11679.00 922.00 936.30 933.16 937.64 0.009230 9.29 1257.69 825.74 0.55 Reach-1 12080 Bridge Reach-1 12090 PF 1 CEM-CAH 11679.00 922.00 940.40 933.03 940.51 0.000869 3.39 6194.33 878.46 0.17 Reach-1 12090 PF 1 PCM-CAH 11679.00 922.00 940.40 933.03 940.51 0.000869 3.39 6194.33 878.46 0.17 Reach-1 12215 PF 1 CEM-CAH 11679.00 923.00 940.45 940.84 0.003638 8.17 2976.13 339.41 0.36 Reach-1 12215 PF 1 PCM-CAH 11679.00 923.00 940.45 940.84 0.003638 8.17 2976.13 339.41 0.36 Reach-1 13040 PF 1 CEM-CAH 11679.00 926.60 942.47 942.57 0.001322 4.47 5345.01 645.21 0.20 Reach-1 13040 PF 1 PCM-CAH 11679.00 926.60 942.47 942.57 0.001322 4.47 5345.01 645.21 0.20 Reach-1 14450 PF 1 CEM-CAH 11679.00 930.60 945.18 945.69 0.004637 8.31 3290.49 643.31 0.40 Reach-1 14450 PF 1 PCM-CAH 11679.00 930.60 945.18 945.69 0.004637 8.31 3290.49 643.31 0.40 Reach-1 15520 PF 1 CEM-CAH 11679.00 933.50 949.85 950.76 0.005306 9.27 2284.77 373.56 0.44 Reach-1 15520 PF 1 PCM-CAH 11679.00 933.50 949.85 950.76 0.005306 9.27 2284.77 373.56 0.44 Reach-1 16130 PF 1 CEM-CAH 11679.00 934.30 953.08 954.60 0.006717 11.82 1770.54 239.17 0.51 HEC-RAS River: RIVER-1 Reach: Reach-1 Profile: PF 1 (Continued) Reach River Sta Profile Plan Q Total Min Ch El W.S. Elev Crit W.S. E.G. Elev E.G. Slope Vel Chnl Flow Area Top Width Froude # Chl (cfs) (ft) (ft) (ft) (ft) (ft/ft) (ft/s) (sq ft) (ft) Reach-1 16130 PF 1 PCM-CAH 11679.00 934.30 953.08 954.60 0.006717 11.82 1770.54 239.17 0.51 Reach-1 16425 PF 1 CEM-CAH 11679.00 936.00 955.00 956.58 0.006551 12.14 2081.66 437.00 0.51 Reach-1 16425 PF 1 PCM-CAH 11679.00 936.00 955.00 956.58 0.006551 12.14 2081.66 437.00 0.51 Reach-1 16920 PF 1 CEM-CAH 11679.00 939.00 957.69 957.92 0.001105 5.00 4191.62 537.74 0.21 Reach-1 16920 PF 1 PCM-CAH 11679.00 939.00 957.69 957.92 0.001105 5.00 4191.62 537.74 0.21 Reach-1 18500 PF 1 CEM-CAH 11450.00 943.10 960.11 960.37 0.002359 6.01 3650.95 495.00 0.28 Reach-1 18500 PF 1 PCM-CAH 11450.00 943.10 960.11 960.37 0.002359 6.01 3650.95 495.00 0.28 Reach-1 19530 PF 1 CEM-CAH 11450.00 947.00 962.11 962.25 0.001726 5.12 4842.84 663.00 0.25 Reach-1 19530 PF 1 PCM-CAH 11450.00 947.00 962.11 962.25 0.001726 5.12 4842.84 663.00 0.25 Reach-1 20710 PF 1 CEM-CAH 11450.00 951.80 964.19 964.52 0.003969 6.67 3366.26 576.84 0.36 Reach-1 20710 PF 1 PCM-CAH 11450.00 951.80 964.19 964.52 0.003969 6.67 3366.26 576.84 0.36 Reach-1 20860 PF 1 CEM-CAH 11450.00 953.00 964.23 965.82 0.008967 10.61 1429.42 269.81 0.57 Reach-1 20860 PF 1 PCM-CAH 11450.00 953.00 964.23 965.82 0.008967 10.61 1429.42 269.81 0.57 Reach-1 20880 PF 1 CEM-CAH 11450.00 953.00 964.18 961.00 966.22 0.013488 11.46 999.02 267.11 0.61 Reach-1 20880 PF 1 PCM-CAH 11450.00 953.00 964.18 961.00 966.22 0.013488 11.46 999.02 267.11 0.61 Reach-1 20890 Bridge Reach-1 20900 PF 1 CEM-CAH 11450.00 953.00 964.89 961.00 966.69 0.011178 10.78 1062.30 294.70 0.55 Reach-1 20900 PF 1 PCM-CAH 11450.00 953.00 964.89 961.00 966.69 0.011178 10.78 1062.30 294.70 0.55 Reach-1 20910 PF 1 CEM-CAH 11450.00 953.00 966.63 967.04 0.003839 7.33 3426.29 643.96 0.37 Reach-1 20910 PF 1 PCM-CAH 11450.00 953.00 966.63 967.04 0.003839 7.33 3426.29 643.96 0.37 Reach-1 21100 PF 1 CEM-CAH 11450.00 953.00 967.31 967.80 0.003905 7.67 2962.33 452.93 0.38 Reach-1 21100 PF 1 PCM-CAH 11450.00 953.00 967.31 967.80 0.003905 7.67 2962.33 452.93 0.38 Reach-1 21970 PF 1 CEM-CAH 11450.00 955.00 969.95 970.15 0.002216 5.61 4492.26 718.22 0.28 Reach-1 21970 PF 1 PCM-CAH 11450.00 955.00 969.95 970.15 0.002216 5.61 4492.26 718.22 0.28 Reach-1 22650 PF 1 CEM-CAH 11450.00 958.00 971.93 972.67 0.005905 9.29 2379.42 363.42 0.46 Reach-1 22650 PF 1 PCM-CAH 11450.00 958.00 971.93 972.67 0.005905 9.29 2379.42 363.42 0.46 Reach-1 23610 PF 1 CEM-CAH 11450.00 961.00 977.27 978.43 0.006455 10.05 1808.02 250.18 0.48 Reach-1 23610 PF 1 PCM-CAH 11450.00 961.00 977.27 978.43 0.006455 10.05 1808.02 250.18 0.48 Reach-1 24560 PF 1 CEM-CAH 11450.00 968.00 981.28 981.56 0.001968 5.54 3442.83 421.41 0.27 Reach-1 24560 PF 1 PCM-CAH 11450.00 968.00 981.28 981.56 0.001968 5.54 3442.83 421.41 0.27 Reach-1 24590 PF 1 CEM-CAH 11450.00 968.00 981.34 977.32 981.61 0.001946 5.53 3463.81 386.60 0.27 Reach-1 24590 PF 1 PCM-CAH 11450.00 968.00 981.34 977.32 981.61 0.001946 5.53 3463.81 386.60 0.27 Reach-1 24600 Bridge Reach-1 24610 PF 1 CEM-CAH 11450.00 968.00 983.38 977.32 983.56 0.001079 4.54 4283.00 414.55 0.21 Reach-1 24610 PF 1 PCM-CAH 11450.00 968.00 983.38 977.32 983.56 0.001079 4.54 4283.00 414.55 0.21 Reach-1 24660 PF 1 CEM-CAH 11450.00 968.30 982.81 984.14 0.007478 10.32 1771.32 329.35 0.51 Reach-1 24660 PF 1 PCM-CAH 11450.00 968.30 982.81 984.14 0.007478 10.32 1771.32 329.35 0.51 Reach-1 24805 PF 1 CEM-CAH 11450.00 968.30 984.19 985.07 0.004540 8.62 2261.93 378.11 0.41 Reach-1 24805 PF 1 PCM-CAH 11450.00 968.30 984.19 985.07 0.004540 8.62 2261.93 378.11 0.41 Reach-1 24955 PF 1 CEM-CAH 11450.00 968.00 984.82 985.61 0.002772 7.20 1738.76 201.41 0.31 Reach-1 24955 PF 1 PCM-CAH 11450.00 968.00 984.82 985.61 0.002772 7.20 1738.76 201.41 0.31 Reach-1 24960 PF 1 CEM-CAH 11450.00 968.00 984.83 975.79 985.62 0.002762 7.19 1742.03 202.34 0.31 Reach-1 24960 PF 1 PCM-CAH 11450.00 968.00 984.83 975.79 985.62 0.002762 7.19 1742.03 202.34 0.31 Reach-1 24967.5 Bridge Reach-1 24975 PF 1 CEM-CAH 11450.00 968.00 985.11 975.79 985.92 0.002707 7.19 1591.62 218.40 0.31 Reach-1 24975 PF 1 PCM-CAH 11450.00 968.00 985.11 975.79 985.92 0.002707 7.19 1591.62 218.40 0.31 Reach-1 24995 PF 1 CEM-CAH 11450.00 968.00 985.24 975.79 985.98 0.002530 6.99 1828.86 225.50 0.30 Reach-1 24995 PF 1 PCM-CAH 11450.00 968.00 985.24 975.79 985.98 0.002530 6.99 1828.86 225.50 0.30 Reach-1 25002.5 Bridge Reach-1 25010 PF 1 CEM-CAH 11450.00 968.00 985.54 975.79 986.30 0.002495 7.02 1631.04 242.59 0.30 Reach-1 25010 PF 1 PCM-CAH 11450.00 968.00 985.54 975.79 986.30 0.002495 7.02 1631.04 242.59 0.30 Reach-1 25050 PF 1 CEM-CAH 11383.00 965.20 984.86 987.04 0.008761 12.24 1164.06 148.47 0.51 Reach-1 25050 PF 1 PCM-CAH 11383.00 965.20 984.86 987.04 0.008761 12.24 1164.06 148.47 0.51 HEC-RAS River: RIVER-1 Reach: Reach-1 Profile: PF 1 (Continued) Reach River Sta Profile Plan Q Total Min Ch El W.S. Elev Crit W.S. E.G. Elev E.G. Slope Vel Chnl Flow Area Top Width Froude # Chl (cfs) (ft) (ft) (ft) (ft) (ft/ft) (ft/s) (sq ft) (ft) Reach-1 25165 PF 1 CEM-CAH 11383.00 965.70 985.97 988.22 0.011554 13.58 1359.33 216.19 0.57 Reach-1 25165 PF 1 PCM-CAH 11383.00 965.70 985.97 988.22 0.011554 13.58 1359.33 216.19 0.57 Reach-1 26040 PF 1 CEM-CAH 10090.00 970.20 993.05 993.53 0.003118 7.60 2617.21 327.04 0.30 Reach-1 26040 PF 1 PCM-CAH 10090.00 970.20 993.05 993.53 0.003118 7.60 2617.21 327.04 0.30 Reach-1 26920 PF 1 CEM-CAH 10090.00 975.30 994.87 995.08 0.001196 5.01 3945.54 460.60 0.21 Reach-1 26920 PF 1 PCM-CAH 10090.00 975.30 994.87 995.08 0.001196 5.01 3945.54 460.60 0.21 Reach-1 27020 PF 1 CEM-CAH 10090.00 975.00 995.06 988.32 995.21 0.001261 4.66 4199.47 472.45 0.18 Reach-1 27020 PF 1 PCM-CAH 10090.00 975.00 995.06 988.32 995.21 0.001261 4.66 4199.47 472.45 0.18 Reach-1 27026 Bridge Reach-1 27032 PF 1 CEM-CAH 10090.00 975.00 995.15 988.31 995.31 0.001223 4.61 4245.79 473.23 0.18 Reach-1 27032 PF 1 PCM-CAH 10090.00 975.00 995.15 988.31 995.31 0.001223 4.61 4245.79 473.23 0.18 Reach-1 27060 PF 1 CEM-CAH 10090.00 975.20 994.94 995.50 0.000988 7.24 3303.65 418.50 0.31 Reach-1 27060 PF 1 PCM-CAH 10090.00 975.20 994.94 995.50 0.000988 7.24 3303.65 418.50 0.31 Reach-1 27734 PF 1 CEM-CAH 10090.00 977.90 995.68 996.74 0.002799 12.42 2957.72 430.86 0.53 Reach-1 27734 PF 1 PCM-CAH 10090.00 977.90 995.68 996.74 0.002799 12.42 2957.72 430.86 0.53 Reach-1 27778 PF 1 CEM-CAH 10090.00 979.00 996.10 991.80 996.90 0.002249 9.20 2777.92 417.69 0.42 Reach-1 27778 PF 1 PCM-CAH 10090.00 979.00 996.10 991.80 996.90 0.002249 9.20 2777.92 417.69 0.42 Reach-1 27790 Bridge Reach-1 27802 PF 1 CEM-CAH 10090.00 979.00 996.25 991.69 996.97 0.002192 8.82 2870.11 422.11 0.40 Reach-1 27802 PF 1 PCM-CAH 10090.00 979.00 996.25 991.69 996.97 0.002192 8.82 2870.11 422.11 0.40 Reach-1 27836 PF 1 CEM-CAH 10090.00 978.60 996.08 997.20 0.001956 9.85 2313.99 331.76 0.44 Reach-1 27836 PF 1 PCM-CAH 10090.00 978.60 996.08 997.20 0.001956 9.85 2313.99 331.76 0.44 Reach-1 28980 PF 1 CEM-CAH 10090.00 982.40 998.74 997.81 1001.55 0.006222 14.75 1301.64 236.93 0.73 Reach-1 28980 PF 1 PCM-CAH 10090.00 982.40 998.74 997.81 1001.55 0.006222 14.75 1301.64 236.93 0.73 0 100 200 300 400 500 980 985 990 995 1000 1005 1010 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 28980 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - CEM-CAH EG PF 1 - PCM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Crit PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Bank Sta .12 .04 .12 100 150 200 250 300 350 400 450 905 910 915 920 925 930 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 5046 This is a REPEATED section. Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - CEM-CAH EG PF 1 - PCM-CAH WS PF 1 - CEM-CAH WS PF 1 - PCM-CAH Crit PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Ineff Bank Sta .11 .065 .11 100 150 200 250 300 350 400 450 905 910 915 920 925 930 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 5040 BR Bridge #4 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - CEM-CAH EG PF 1 - PCM-CAH WS PF 1 - CEM-CAH WS PF 1 - PCM-CAH Crit PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Ineff Bank Sta .11 .065 .11 100 150 200 250 300 350 400 450 905 910 915 920 925 930 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 5040 BR Bridge #4 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH EG PF 1 - CEM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Crit PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Ineff Bank Sta .11 .065 .11 100 150 200 250 300 350 400 450 905 910 915 920 925 930 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 5034 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH EG PF 1 - CEM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Crit PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Ineff Bank Sta .11 .065 .11 50 100 150 200 250 300 350 400 450 905 910 915 920 925 930 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4950 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH EG PF 1 - CEM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Ground Bank Sta .11 .065 .11 750 800 850 900 950 1000 1050 1100 1150 900 905 910 915 920 925 930 935 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4500 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH EG PF 1 - CEM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Ground Bank Sta .11 .065 .11 0 200 400 600 800 1000 890 900 910 920 930 940 950 960 970 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4250 New Cross Section - Adj. to NGVD27 (+0.65') Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH EG PF 1 - CEM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Bank Sta .11 .065 .11 0 200 400 600 800 1000 890 900 910 920 930 940 950 960 970 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4235 BR Gish Mill Deck Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH WS PF 1 - PCM-CAH Crit PF 1 - PCM-CAH Ground Bank Sta .11 .065 .11 0 200 400 600 800 1000 890 900 910 920 930 940 950 960 970 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4235 BR Gish Mill Deck Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - PCM-CAH WS PF 1 - PCM-CAH Crit PF 1 - PCM-CAH Ground Bank Sta .11 .065 .11 0 200 400 600 800 1000 890 900 910 920 930 940 950 960 970 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4210 Copy of Section 4250 Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - CEM-CAH EG PF 1 - PCM-CAH WS PF 1 - CEM-CAH WS PF 1 - PCM-CAH Ground Bank Sta .11 .065 .11 0 200 400 600 800 1000 890 900 910 920 930 940 950 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4150 Section adjusted per survey Adj. to NGVD27 (+0.65') Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - CEM-CAH EG PF 1 - PCM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Ground Bank Sta .11 .065 .11 0 200 400 600 800 1000 895 900 905 910 915 920 925 930 935 GladeCreek Plan: 1) CEM-CAH 3/5/2021 2) PCM-CAH 3/5/2021 RS = 4048 This is a REPEATED section. Station (ft) El e v a t i o n ( f t ) Legend EG PF 1 - CEM-CAH EG PF 1 - PCM-CAH WS PF 1 - PCM-CAH WS PF 1 - CEM-CAH Crit PF 1 - CEM-CAH Crit PF 1 - PCM-CAH Ground Ineff Bank Sta .11 .065 .11 Attachment C Letter from the Department of Historic Resources Concerning Historic Designation of Gish Mill Property Gish Mill Redevelopment Project March 16, 2020 Town of Vinton Rezoning Request Town Council Briefing Nature of Request •Petition of the Town of Vinton, to rezone the historic Gish Mill properties, from M-1 Limited Industrial to Mixed Use Development (MUD) District, in order for the properties to be redeveloped into a mixed-use property that will accommodate restaurant, retail, residential, and lodging uses. The properties are located at 350 and 0 Gus Nicks Boulevard, Vinton, Virginia, Tax Map Numbers 060.11-04-22.00-0000 and 060.11-04-23.00-0000. 2 Planning and Zoning Department Timeline of Events •October 23, 2015: Town of Vinton purchases Gish Mill property. •2019: Issuance of a Request for Proposal (RFP), which the Gish Mill Davii, LLC responded to with a formal proposal to convert the historic property into a mixed-use development. •April 8, 2020: Contract of Sale between Town and Development Team is signed. •Fall 2020: Town awarded grant funds from two state government agencies. •The first grant from the Department of Historic Resources (DHR) Emergency Supplemental Historic Preservation Fund (ESHPF) grant program includes $250,000 in available funding for repair and stabilization work to take place on the property. •The second grant to the Town is to be administered in the form of a loan of $468,750 through the Economic Development Authority (EDA) from the Department of Housing and Community Development (DHCD) Industrial Revitalization Fund (IRF). 3 Planning and Zoning Department Timeline of Events •March 5, 2021: No-rise certification attained after the completion of a H&H study by Draper Aden Associates. •March 16, 2021: Notification letters sent out to adjoining property owners. Upcoming Events: •March 25, 2021: Planning Commission work session. •March 30, 2021: BZA public hearing on variance request by the Town of Vinton. •April 6, 2021: Joint public hearing of the Planning Commission and Town Council on the rezoning request. 4 Planning and Zoning Department Basic Information on Properties •Location: 350 and 0 Gus Nicks Boulevard, Vinton, Virginia. Former Holdren’s County Store. •Topography/Vegetation –The existing structure is located adjacent to Glade Creek on a level lot that is comprised mostly of impervious surfaces. In relation to its special location, the Gish Mill, in serving its historic purposes, is located in the regulatory floodway and Special Flood Hazard Areas (SFHA) of the Glade Creek floodplain. •Site Access: The parcels can be accessed from Gus Nicks Boulevard and West Madison Avenue. •Adjacent Zoning and Land Uses: 5 Direction from Property Zoning District Land Use North N/A Glade Creek/ Roanoke City Parcel (RM-1) West MUD Apartment Building/ Future Business Flex Space Southeast M-1 Limited Industrial Clothing embroidery (Chalaine’s) and Sign Manufacturing (Sav’ On Signs) Businesses South N/A Right-of-way Planning and Zoning Department Adjacent Zoning and Land Uses 6 Planning and Zoning Department Regulatory Floodway and Special Flood Hazard Areas (SFHA) 7 Planning and Zoning Department No-Rise Certification •The Town utilized the consulting services of Draper Aden Associates to verify that the proposed redevelopment project would not cause a rise in the base flood elevation.The consultants were able to utilize the plans of the proposed improvements from the development team and implement them into the flood models.The conclusion of this H&H study was that the proposed project will not cause a rise in the base flood elevations. 8 Planning and Zoning Department Floodplain Variance Process (BZA) •The Gish Mill structure meets the definition of a “historic structure” set out in the definition section of Division 13, FO Floodplain Overlay District, of the Vinton Zoning Ordinance. Specifically, the Gish Mill structure meets the definition of subsection (a) pertaining to being “preliminary determined” for individual listing on the National Register. •Both the Town of Vinton and the Development Team understand that meeting this definition does not automatically exempt this project and its associated activities from the requirements of the floodplain ordinance. However, specific variances from the floodplain ordinance are being requested by the Town of Vinton with a public hearing of the Board of Zoning Appeals scheduled for March 30, 2021. 9 Planning and Zoning Department Current Conditions of Property 10 Planning and Zoning Department Current Conditions of Property Planning and Zoning Department11 Current Conditions of Property 12 Planning and Zoning Department Current Conditions of Property 13 Planning and Zoning Department Current Conditions of Property 14 Planning and Zoning Department Current Conditions of Property 15 Planning and Zoning Department Current Conditions of Property 16 Planning and Zoning Department Analysis of Proposed Redevelopment The Gish Mill Davii, LLC & Hill Studio, PC Presented by: Overview •The developer’s intended use for the mill site is to incorporate several value-added compatible uses,which launch from popular trends that work very well with the open format historic space.The building will be designed to feature several uses that take advantage of the creekside location,the unconventional construction methods,and varying dimensions and angles featured by the mill space.The specific uses include a small restaurant,a seasonal market,a speakeasy in the basement,and the conversion of the original mill structure, concrete silos,and upper floors of the original mill structure into lodging or apartments (3-10 units). •The anticipated tenant to operate the restaurant and lodge has already been secured for the project.The development also includes substantial outdoor spaces including dining,deck, and patio space.The historic “sluice”will be utilized as an intimate seating area with stairs that cascade down to the creek. 18 Square Footage of Uses •Based on the preliminary floor plans,the development will include: •(1)Restaurant (back of house,kitchen,and dining space):5,030 square feet (First floor) •(2)Market:1,250 square feet (First floor) •(3)Speakeasy:1,296 square feet (Basement) •(4)Original Mill and silos converted into lodging/apartments:5,800 square feet (Second and Third floor) •(5)Outdoor dining,deck and patio space:3,564 square feet (including the deck and patio area utilizing the existing slab) 19 Comprehensive Plan/Future Land Use •The 2004 –2024 Town Comprehensive Plan designates this property and the surrounding properties to the southeast as a general commercial land use area.The properties to the west of this property (across Gus Nicks Boulevard)are designated as parks and recreation,community facilities, and high density residential uses.The properties to the west were rezoned to Mixed Use Development (MUD)in 2016 to allow for the existing vacant school buildings to be adaptively reused as residential and recreational/small business flex space. 34 Planning and Zoning Department Staff Conclusion •Approval of the proposed rezoning from M-1 Limited Industrial to Mixed Use Development (MUD) District would allow the existing Gish Mill property to be redeveloped into a mixed-use property that will accommodate restaurant, retail, residential, and lodging uses. The proposed redevelopment of the historic Gish Mill property would be consistent with the existing uses of the adjoining properties to the west and southeast which contain both residential and commercial uses. •The redevelopment of the property will promote and encourage the economic vitality of the community and preserve a historic building while providing increased economic investment. Additionally, the proposed uses will not adversely affect adjoining properties and will enhance the neighborhood by taking an important historical structure and repurposing it for a suitable alternative use that maintains the historic architecture and setting of the buildings. Adequate utilities and public facilities are already in place to serve the proposed end uses. 35 Planning and Zoning Department Staff Conclusion (cont.) •Overall, the rezoning of the parcels included in the Gish Mill site will be the third MUD rezoning process in the Town of Vinton. The other two projects that involved the rezoning of parcels to MUD in the Town of Vinton included the Roland E. Cook Lofts and the Billy Byrd Apartment projects, which were formerly owned by Roanoke County Board of Supervisors. The Roland E. Cook Lofts and Billy Byrd Apartments projects have proven to be a benchmark of success in the revitalization of historic buildings through the utilization of historic tax credit programs and local governmental (County of Roanoke and Town of Vinton) coordination. 36 Planning and Zoning Department Questions? Planning and Zoning Department Capital Improvement Discussion Town Council Retreat –March 5, 2021 Fund Balance Discussion •Eligible From Fund Balance: $1,042,489 •Eligible From Current Year Revenue: $500,000 •FY22 CIP Budget: $550,000.00 •Available Budget: $2,092,489 •Options for Consideration : •Capital Improvement Program •PTO Conversion from Sick/Vacation Leave •Early Debt Retirement •Other Town of Vinton, Virginia 2 Current Year Appropriation General Fund Balance / Current Year Revenue Department/Strategic Goal Description / Location Cost HR / Finance -2 Vacation and Sick Leave Accrual Liability Payout $350,000 Town-1 Municipal Building-window replacement-lost “R” factor $35,000 Town-1 Municipal Building-HVAC-last remaining unit to be replaced $13,000 Town-1 Municipal Building-parking lot repaving to include Drive-thru $110,000 Town-1 Municipal Building-lighting -replacing wall packs, pedestal, awning lights $20,000 Town-1 Municipal Building Manager’s Suite and Finance Office work spaces $30,000 Public Works-1 Clearview Traffic Signal:Replace and Update Signals,Control Box, Cabling, Camera, Battery Supply $65,000 Town of Vinton, Virginia 3 Town of Vinton, Virginia 4 General Fund Balance / Current Year Revenue Department/Strategic Goal Description / Location Cost Public Works-1 Hardy Road paving-CVS to Town Limits $423,971 Stormwater / Utility-1 Streambank Stabilization $160,000 Econ Dev-3 Gish Mill Building Delivery-Scaffolding, tree removal and debris disposal $50,000 Total Request Current Year Projects $1,256,971 Public Works-1 Rebuild and Repair Road Surface VDOT Rev. Sharing Match FY25-FY26*$550,000 *currently on hold in reserve Current Year Appropriation (continued) Town of Vinton, Virginia 5 General Fund Department/Strategic Goal Description / Location Cost Community Dev-1 Replace and Update Five Gateway Entrance Signs w/ Landscaping $40,000 Community Dev-1 Greenway Phase 2B VDOT Match $50,000 Econ Dev-3 Gish Mill Parking & Facade $250,000 Public Works-2 Worksite and Work Zone Safety Package $20,000 Public Works-1 Traffic Signal Improvements, Various Intersections $150,000 Town / Finance-2 ERP Software Replacement (remaining balance)$200,000 Community Programs-1 Museum Electrical Upgrades, Porch Repair, Basement Waterproofing $15,000 Community Dev-1 Streetscape Planters $10,000 Police Department-2 Body Cameras $100,000 Total $835,000 FY 22 Capital Projects Town of Vinton, Virginia 6 Utility Fund Department/Strategic Goal Description / Location Cost Utility Fund-1 SCADA System Upgrade**$370,000 Utility Fund-1 Water Meter Upgrade Phase 2**$2,050,000 Utility Fund-1 Renovate and Upgrade 3rd St. Sewer Lift Station**$1,950,000 Total Request $4,370,000 **Debt Issuance 2021 FY 22 Capital Projects Utility Fund Town of Vinton, Virginia 7 General Fund Department/Strategic Goal Description / Location Cost Police Dept-2 TASER Replacement $21,177 Police Dept-2 Radar Replacement $37,000 Public Works-2 Wood Chipper $42,000 Community Programs-1 Swimming Pool Closure-Fill and Cap for future park construction $65,000 Community Programs-1 Install Skate Park w/ Park Amenities $75,000 Planning & Zoning-1 Greenway Phase 2B VDOT Match $50,000 Public Works-1 Traffic Signal Improvements, Various Intersections $150,000 Public Works-1 Sidewalks –Vinyard Rd $100,000 Total $540,178 FY23 Capital Projects Town of Vinton, Virginia 8 FY23 Capital Projects Utility Fund Utility-2 $105,000 Utility-1 $100,000 Total $205,000 Stormwater-2 Stormwater Capital Study $100,000 Total $100,000 Department/Strategic Goal Description / Location Cost Town of Vinton, Virginia 9 General Fund Department/Strategic Goal Description / Location Cost Public Works-2 Replace Fuel Pumps $35,000 Public Works-2 Traffic Signal Improvements, Various Intersections $200,000 Public Works-2 Dump Truck, Snowplow & Salt Spreader $154,000 Public Works-2 $60,000 Community Dev-1 –Bypass Rd $100,000 Total $549,000 FY24 Capital Projects Utility-1 Meadows Well Opening $350,000 Total $350,000 Town of Vinton, Virginia 10 Department/Strategic Goal Description / Location Cost Public Works-1 $200,000 Public Works-1 $200,000 Community Dev-1 –Cleveland $150,000 Total $550,000 Utility-2 Sewer Easement Jetter $70,000 Utility-1 Pitt/Peake Water Line Replacement $50,000 Total $105,000 FY 25 Capital Projects Town of Vinton, Virginia 11 Department/Strategic Goal Description / Location Cost Public Works-1 Bridge Maintenance, Garthright Bridge $200,000 Public Works-2 Traffic Signal Improvements, Various Intersections $200,000 Public Works-1 Mnt View Rd Contingency $100,000 Public Works-1 and Transfer Switchgear $30,000 Total $530,000 Utility-1 Valley Hall Water Line Replacement/Realignment $64,500 Utility-2 Pick up Truck, HD4500 with Dump Body $58,100 Total $122,600 FY 26 Capital Projects Town of Vinton, Virginia 12 Department/Strategic Goal Description / Location Cost Public Works-1 $26,100 Public Works-1 $30,350 Public Works-1 $42,000 Public Works-2 $74,000 Town-1 $250,000 Public Works-2 $125,000 Total $547,450 FY 27 Capital Projects Town of Vinton, Virginia 13 Department/Strategic Goal Description / Location Cost Public Works-2 $100,000 Public Works-2 -Frontend Loader $110,000 Community Dev-1 $100,000 Public Works-2 $300,000 Public Works-1 $22,000 Total $632,000 FY 28 Capital Projects Current Year PTO Conversion 350,000.00 Municipal Bldg Window Replacement 35,000.00 Municipal Bldg HVAC 13,000.00 Municipal Bldg Parking Lot Repaving 110,000.00 Lighting 20,000.00 Furniture 30,000.00 Clearview Traffic Signal Updates 65,000.00 Hardy Rd Paving 423,971.00 Glade Creek Streambank Stabilization 160,000.00 Gish Mill Delivery 50,000.00 TOTAL 1,256,971.00 Town of Vinton, Virginia Council Retreat Current Year Projects FY22 Gateway Signs 40,000.00 Glade Creek 2b match 50,000.00 Gish Mill Parking & Façade 250,000.00 Worksite and Work Zone Safety Package 20,000.00 Traffc Signal Improvements, Various Intersections 150,000.00 ERP Software Replacement (remaining balance)200,000.00 Museum Repairs 15,000.00 Planters 10,000.00 Body Cameras 100,000.00 TOTAL 835,000.00 FY23 TASER Replacement 21,178.00 Radar Replacement 37,000.00 Wood Chipper 42,000.00 Pool Closure 65,000.00 Skate Park 75,000.00 Glade Creek 2b match 50,000.00 Traffc Signal Improvements, Various Intersections 150,000.00 Sidewalks - Vinyard 100,000.00 TOTAL 540,178.00 FY24 Replace Fuel Pumps 35,000.00 Traffc Signal Improvements, Various Intersections 200,000.00 Dump Truck, Snowplow & Salt Spreader 154,000.00 Underground Fuel Storage Tanks 60,000.00 Sidewalks - Bypass Rd 100,000.00 TOTAL 549,000.00 FY25 Traffc Signal Improvements, Various Intersections 200,000.00 Bridge Maintenance, Garthright Bridge 200,000.00 Sidewalks - Cleveland 150,000.00 TOTAL 550,000.00 FY26 Bridge Maintenance, Garthright Bridge 200,000.00 Traffc Signal Improvements, Various Intersections 200,000.00 Mnt View Rd Rev Sharing Contingency 100,000.00 Connection and Transfer Switchgear 30,000.00 TOTAL 530,000.00 FY27 Install Guardrails, Giles Avenue 26,100.00 Install Guardrails, Third Street 30,350.00 Install Guardrails, Niagara Road/Woodland Place 42,000.00 Enclose Equipment Shelter 74,000.00 Municipal Building Roof Replacement 250,000.00 PW Storage Area, Repairs & Improvements 125,000.00 TOTAL 547,450.00 FY28 Reconstruct Public Works Parking Lot 100,000.00 Replace Backhoe-Frontend Loader 110,000.00 Wolf Creek Greenway Bathroom 100,000.00 Refuse Truck Replacement 300,000.00 Install Guardrails, Chestnut Avenue 22,000.00 632,000.00 Town of Vinton, Virginia Council Retreat FY22-28 CIP Planning Worksheet 1 RESOLUTION NO. 2418 AT A REGULAR MEETING OF THE VINTON TOWN COUNCIL HELD ON TUESDAY, MARCH 16, 2021 AT 7:00 P.M., BY ELECTRONIC COMMUNICATIONS PURSUANT TO SECTION 15.2-1413, CODE OF VIRGINIA (1950), AS AMENDED, ORDINANCE NO. 1016, AND SECTION 4-0.01(G) OF CHAPTER 1289 OF THE 2020 ACTS OF THE VIRGINIA GENERAL ASSEMBLY WHEREAS, as of the June 30, 2020 Audited Financial Statements, the Town had an Unrestricted Fund Balance of $3,668,974; and WHEREAS, the Town’s General Fund Reserve Policy allows for use of excess Unrestricted Fund Balance above the required level to be appropriated by Town Council to fund additional capital improvement plan items or one-time projects; and WHEREAS, Town Staff briefed the Town Council on an updated capital improvement plan and one-time project needs at the Town Council Retreat on March 5, 2021; and WHEREAS, an appropriation of $906,971 is proposed to be transferred from the General Fund to the Capital Fund to complete the capital items such as upgrades to the Municipal Building to include window replacement, HVAC replacement, parking lot repaving, lighting upgrade, furniture and equipment upgrade, and additional upgrades to include Clearview traffic signal upgrades, Hardy Road repaving, Gish Mill delivery, Storm Water Engineering Analysis and Glade Creek Streambank Stabilization; and WHEREAS, an additional $285,000 of funding is proposed to be transferred from the General Fund to the Capital Fund for additional capital projects included in the Capital Improvement Program (CIP) to be completed in FY2022; and WHEREAS, funding for projects not completed at the fiscal year end of 2021 will be rolled forward in the Fund Balance designated in the Capital Fund for project completion in the following fiscal year(s). NOW THEREFORE, BE IT RESOLVED, that the Vinton Town Council does hereby approve the following transaction: BUDGET ENTRY GENERAL LEDGER 200.25100 Appropriations $1,191,971 200.25000 Estimated Revenue $1,191,971 400.25100 Appropriations $1,031,971 400.25000 Estimated Revenue $1,031,971 600.25100 Appropriations $160,000 600.25000 Estimated Revenue $160,000 TOTAL $2,383,942 $2,383,942 2 REVENUE 200.1899.009 Re-Appropriated Fund Balance $1,041,971 200.2402.001 State Sales Tax $150,000 400.4105.001 Transfer from General Fund $1,031,971 600.4105.001 Transfer from General Fund $160,000 TOTAL $2,383,942 EXPENDITURE 200.9950.905 Transfer to Capital Fund $1,031,971 200.9950.900 Transfer to Storm Water Fund $160,000 400.4304.720 Muni. Bldg. Window Replacement $35,000 400.4304.725 Muni. Bldg. HVAC Replacement $13,000 400.4304.781 Muni. Bldg. Parking Lot Repaving $110,000 400.4304.722 Lighting Upgrade $20,000 400.4304.702 Muni. Bldg. Furniture & Equipment $30,000 400.4108.799 Clearview Traffic Signal Updates $65,000 400.4101.781 Hardy Road Paving $423,971 400.8150.724 Gish Mill Delivery $50,000 400.9950.910 Non-Department Transfers $285,000 600.6205.799 Glade Creek Streambank Stabilization $160,000 TOTAL $2,383,942 This Resolution adopted on motion made by Council Member Liles, seconded by Vice Mayor McCarty, with the following votes recorded: AYES: Liles, Mullins, McCarty, Grose NAYS: None ABSENT: Stovall APPROVED: Bradley E. Grose, Mayor ATTEST: ________________________________ Susan N. Johnson, CMC, Town Clerk Please print in the LEGALS section of the Classifieds for the Vinton Messenger on: March 18, 2021. Please send affidavit of publication to: Nathaniel McClung Planning and Zoning 311 S. Pollard Street Vinton, VA 24179 540-983-0605 nmcclung@vintonva.gov __________________________________________________________________________ PUBLIC NOTICE The Planning Commission of Town of Vinton, Virginia, hereby gives notice of a work session on Thursday, March 25, 2021, at 6:30 p.m. The purpose of the work session is to receive comments and discuss the request to rezone the historic Gish Mill properties, located at 350 and 0 Gus Nicks Boulevard, Vinton, Virginia, Tax Map Numbers 060.11-04-22.00-0000 and 060.11-04-23.00-0000, from M-1 Limited Industrial to Mixed Use Development (MUD) District, and to review the proposed Capital Improvement Plan (CIP) of the Town of Vinton. Further information concerning the work session, may be obtained from the Planning and Zoning Department located at 311 South Pollard Street, Vinton, Virginia 24179, by phone: 540-983-0605. Interested persons may be heard at the above work session. In light of the ongoing COVID-19 emergency, participation in this work session by Planning Commission members, staff, and the public will be available through electronic or other alternative means. The public may comment on this request by emailing nmcclung@vintonva.gov, by calling 540-983-0605 or writing to the Principal Planner, Town of Vinton, 311 S. Pollard Street, Vinton, Virginia 24179. Voicemails, emails and other messages containing comments on the request will be provided to both the Commission and Council members. The public also may be able to comment during the electronic work session. Citizens interested in this option must register in advance by calling the Town Clerk’s Office at 540-983-0607 or sending an email to sjohnson@vintonva.gov by 12 Noon on Wednesday, March 24, 2021. The public can observe this meeting through a livestream on the Town’s Facebook page at www.facebook.com/vintonva. Additional information concerning the work session will be made available on the Town’s website at least three days before the meeting date. Comments and grievances can be submitted in writing to the Town Manager’s Office, Town of Vinton, Virginia at 311 South Pollard Street, Vinton, VA 24179 or by phone at (540) 983- 0607, or Virginia Relay Service 711 until March 25, 2021 at 5pm. Persons requiring special assistance to attend and participate in this public meeting should contact the Town Manager’s Office at (540) 983-0607. NOTICE OF INTENT TO COMPLY WITH DISABILITIES ACT. efforts will be made to provide assistance or special arrangements to qualified individuals with disabilities in order to participate in or attend the meetings. Please call (540) 983- 0605 at least 48 hours prior to the meeting so that proper arrangements may be made. LEGAL NOTICE OF PUBLIC HEARING TO WHOM IT MAY CONCERN: Pursuant to the provisions of Section 15.2-2204 of the 1950 Code of Virginia, as amended, the Town of Vinton, Virginia, hereby gives notice of a joint public hearing to be held by the Planning Commission and the Town Council on Tuesday, April 6, 2021, at 7:00 p.m. The purpose of the public hearing is to receive comments concerning: 1. Petition of the Town of Vinton, to rezone the historic Gish Mill properties, from M-1 Limited Industrial to Mixed Use Development (MUD) District, in order to redevelop them into mixed-use properties that will accommodate restaurant, retail, residential, and lodging uses. The properties are located at 350 and 0 Gus Nicks Boulevard, Vinton, Virginia, Tax Map Numbers 060.11-04-22.00-0000 and 060.11-04-23.00-0000. Further information concerning the public hearing, may be obtained from the Planning and Zoning Department located at 311 South Pollard Street, Vinton, Virginia 24179, by phone: 540-983-0605. Interested persons may be heard at the above public hearing. In light of the ongoing COVID-19 emergency, participation in this public hearing by Planning Commission members, Council members, staff, and the public will be available through electronic or other alternative means. The public may comment on this request by emailing nmcclung@vintonva.gov, by calling 540-983-0605 or writing to the Principal Planner, Town of Vinton, 311 S. Pollard Street, Vinton, Virginia 24179. Voicemails, emails and other messages containing comments on the request will be provided to both the Commission and Council members. The public also may be able to comment during the electronic public hearing. Citizens interested in this option must register in advance by calling the Town Clerk’s Office at 540-983-0607 or sending an email to sjohnson@vintonva.gov by 12 Noon on Monday, April 5, 2021. The public can observe this meeting through a livestream on the Town’s Facebook page at www.facebook.com/vintonva. Additional information concerning the public hearing will be made available on the Town’s website at least three days before the meeting date. Comments and grievances can be submitted in writing to the Town Manager’s Office, Town of Vinton, Virginia at 311 South Pollard Street, Vinton, VA 24179 or by phone at (540) 983-0607, or Virginia Relay Service 711 until April 6, 2021 at 5pm. Persons requiring special assistance to attend and participate in this public meeting should contact the Town Manager’s Office at (540) 983-0607. Anita J. McMillan, Planning and Zoning Director ------------------------------------------------------------------------------------------------------- Please publish in The Vinton Messenger for two Thursdays, March 18, 2021, and March 25, 2021. Please send invoice and affidavit of publication to: Anita J. McMillan Planning and Zoning Office Vinton Municipal Building 311 South Pollard Street Vinton, VA 24179 (540) 983-0605